16) Troubleshooting CH67, CH105
67
105
Outdoor fan
lock
Communication error
between main PCB and
fan PCB
Outdoor fan is not oper-
ating
Communication error
between main PCB
and fan PCB
Check the fan condition.
Check the fan connector
Short or fusing of communication line
Poor outdoor unit PCB
Power input when the DC link capacitor discharges
Display
code
Title Cause of error Check point & Normal condition
Check Point
CH 67
1. Check the install condition for fan.
CH 105
1. Is communication line between the main PCB and the
fan PCB normal?
2. Is the communication LED on?