11) Troubleshooting CH40
V
DC 2.5V
V
Figure 1.
Figure 2.
40
C/T
Sensor Error
Initial current error
Malfunction of current detection circuit.
(Open / Short)
The voltage of "C01N" Is 4.0Vdc(25A) .
Display
code
Title Cause of error Check point & Normal condition
Check Point
1. Check the input voltage.(200~240V)
2. Check the voltage of C01N at not operating.(0V)
3. Check the voltage of Figure2. red point at not operating.(2.5V)