8. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
8.1 Selection of the best location
Indoor unit
• There should not be any heat source or steam near
the unit.
• There should not be any obstacles to prevent the air
circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consid-
eration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
8.2 Indoor unit installation
Installation of Unit
Unit should be installed for horizontal discharge appli-
cation only.
• Apply a joint-canvas between the unit and duct to
absorb unnecessary vibration.
More than
70cm
More than
30cm
More than
70cm
CASE 1
POSITION OF SUSPENSION BOLT
(Unit:mm)
ABC
Dimension
Chassis
VL Chassis 1750 1655 220
VK Chassis 1350 1255 220